You might have seen that in order to start a high power rating induction motor, a starting technique called star-delta is used. In this video, we will understand why a star-delta starter is needed, and how it is accomplished practically with help of animation.
We thank our patrons for making LE’s educational service sustainable. Please support us at Patreon.com so that we will have the capability to release 2 videos/month.
https://www.patreon.com/LearnEngineering
Curious about how LE was born ?, Check out our story : https://goo.gl/otQfvD
Like us on FB : https://www.facebook.com/LearnEngineering
Voice-over artist : https://www.fiverr.com/mikepaine
Understanding STAR-DELTA Starter !
Understanding STAR-DELTA Starter !
Please upload more videos in less time
Love this video ^…^ thank you
Wow
Good.
Having a new method for Residual Current Circuit Breakers can be very helpful for everyone
https://youtu.be/9Lf9csZj0Hg
Very clean informative Clip! 👌
wrong conevtion
Wow!……
best ever
thank you very much.
Now I understand! Better explanation! THANK YOU SIR
Superb animation but language can't understand
seeing this video 1 1/2 year after it has been uploaded and thinking why did i take so long to get there. superb explanation engineering made very easy and interesting. good job and thanks
Amazing video explaining how to do the start up of a 3 phase motor,
Thanks!!
Excellent Video . What is the ideal switching time ?
Nice…
Good tutorial engineering video
This is Old complicated rubbish technology, all motors are going DC rotational flux, fully computer controlled.
3 phase garbage is dying out.
Great video!!! Showing the current direction may help some of us. Great job!
Video not working…
Hindi language me provide kre please…….
Thank you very much for your explanation and animattion.
Please help i have a question, i encountered newly rewind stator without tagging it was a six leads out, then after checking continuity we short the wire not exactly knowing which 123 and 456 is, just assumption. Then connected into delta 1-6 2-4 3-5 then after swicthing it was spark and tripped, but when we connect to wye it was run shorting the assumption of 456 and supply to 123, now my question is let say the people who rewind the motor has mistakenly inserted the wire into the wrong path and re group it instead of 123 and 456 it become now 153 and 426 meaning the 2 and 5 switching,now if i connect it to wye or delta what will happen? Thank you in advance.
Thanks sir
this viseo has been a great aid to teach with thank you 5/5